· The three-wire cabling is properly shielded (the recommended braided shield, no less), landed on PB11, PB12, and PB The PPC is properly outfitted with the NXDBVSD (Modbus and VSD) daughterboard. Parameter (Modbus device address) is set to 1 (on boiler 1), and 2 (on boiler 2). Parameter (Modbus communications speed) is set to 2. refer to the complete installation manual - Fireye bulletin PPC For ease of navigation (see section ), the symbols below will be used throughout the Commissioning Process in this manual to indicate the correct application for each commissioning OPTION, for use by the Commissioning Personnel. This manual describes the installation, commissioning, operation and maintenance of the PPC series fuel air ratio controls. It may be used in conjunction with the following other manuals: Please read the safety information at the front of this manual before proceeding. 1 Technical specification 12 General
This manual describes the installation, commissioning, operation and maintenance of the PPC series fuel air ratio controls. It may be used in conjunction with the following other manuals: Please read the safety information at the front of this manual before proceeding. 1 Technical specification 12 General Fireye Scanners and Controls. Fireye. Scanners and Controls. volt lamp. Test cable for use with C, C, C, and C scanners. Flange gasket for 65UV5. Relay (K1), for Q rack and R controller, Vigitron number Inner carrier (72"), used with CM We can also special order your burner with a Fireye Parallel Positioning Control, either a PPC or a PPC We also carry a full inventory of replacement Fireye Controls including the Flame-Monitor E, BurnerLogix YB and all accessories for these flame safeguards.
Page 1 CONTROLLER DESCRIPTION The Fireye PPC is a state of the art stand-alone parallel positioning system for all types of liquid or gaseous fuel fired combustion systems. When combined with a Fireye flame safeguard system such as the Fireye BurnerLogix control, the PPC offers the most compact and advanced parallel positioning system available. Fireye PPC, the newest member of the Nexus family, is a state of the art parallel positioning system for all types of liquid or gaseous fuel fired combustion systems. When combined with a Fireye flame safeguard system such as the Fireye BurnerLogix control, the PPC offers the most compact and advanced parallel positioning system available. This manual describes the installation, commissioning, operation and maintenance of the PPC series fuel air ratio controls. It may be used in conjunction with the following other manuals: NEX - ComFire combustion analysis tool user manual Please read the safety information at the front of this manual before proceeding.
0コメント